null

Schier GB-75 High-Flow, 75 GPM Indoor/Outdoor Hydromechanical Grease Interceptor (125 Gal. Liquid Capacity)

(No reviews yet) Write a Review
mpn
4045-001-02
SKU:
GB-75
Width:
47.00 (in)
Height:
40.00 (in)
Depth:
33.00 (in)
  • Schier GB-75 High-Flow, 75 GPM Indoor/Outdoor Hydromechanical Grease Interceptor (125 Gal. Liquid Capacity)
  • Schier GB-75 High-Flow, 75 GPM Indoor/Outdoor Hydromechanical Grease Interceptor (125 Gal. Liquid Capacity)
  • Schier GB-75 High-Flow, 75 GPM Indoor/Outdoor Hydromechanical Grease Interceptor (125 Gal. Liquid Capacity)
  • Schier GB-75 High-Flow, 75 GPM Indoor/Outdoor Hydromechanical Grease Interceptor (125 Gal. Liquid Capacity)
  • Schier GB-75 High-Flow, 75 GPM Indoor/Outdoor Hydromechanical Grease Interceptor (125 Gal. Liquid Capacity)
  • Schier GB-75 High-Flow, 75 GPM Indoor/Outdoor Hydromechanical Grease Interceptor (125 Gal. Liquid Capacity)
  • Schier GB-75 High-Flow, 75 GPM Indoor/Outdoor Hydromechanical Grease Interceptor (125 Gal. Liquid Capacity)
$2,774.08

Description

75 GPM Hydromechanical Grease Interceptor

The GB-75 offers best-in-class certified grease capacity and 25% kitchen solids waste capacity. It can be installed above grade (on the ground) or buried below grade (compatible with FCR2 riser to bring system to grade), as well as indoor or outdoor. The triple outlet feature allows for installation flexibility, including the ability to connect an unused outlet for remote pumpout (PP3 compatibility).

Features

  • Rugged polyethylene tank body
  • No flow control required, first in the industry certified to Type D of the ASME standard
  • Safety Star access restrictor prevents accidental entry
  • Fits through 36" doorways

Specs 

1. 4" FPT inlet/outlet with 4" plain end adapters, single inlet and triple outlet.
2. Unit weight - wt cast iron covers: 190 lbs. (For wet weight add 1,043 lbs.)
3. Maximum operating temperature: 150° F continuous
4. Capacities - Liquid: 125 gan. Grease: 861 lbs. (118 gal.) @75 GPM Solids: 31 gal.
5. For gravity drainage applications only.
6. Do not use for pressure applications.
7. Cover placement allows ful:I acx:ess to tank for proper maintenance.
8. Vent not required unless per local code.
9. Engineered inlet and outlet diffusers with inspection ports are removable to inspect / clean piping.
10. Integral air relief I Anti-siphon / Sampling acx:ess.
11. Adjustable cover adapter provides up to 4" of additional height.
12. Designed for below-grade, above-grade, indoor and outdoor installations.
13. Safety Star®, access restrictor built into cover adapter, prevents accidental entry to tank (450 lb rating).

Downloads

Specification Sheet

Installation Guide