Description
The SDMN5 is a portable, rugged dual-port manometer designed especially for HVACR field service technicians. Measures gas pressure, static pressure and pressure differential. The SDMN5 includes a zero adjust button of the face of the meter, a rugged rubber boot, a magnet on the back for hanging the meter during service, and the Auto Power-Off (APO) function conserves battery life. The SDMN5 measures pressure between -60inWC and 60inWC (inches of water column) and -150.0 to 150.0 mBar. The SDMN5 also measures P1 or P2 pressure readings and calculates the difference between P1 and P2. Take static pressure measurements using the resolution mode of 0.01inWC or 0.01mBar. Includes 3/16” to 5/16” adapter for measuring gas inlet and outlet pressures.
The SDMN5 evolved as a result of testing pressures in the field for 20 years. Its range and resolution allow you to measure the HVAC applications you run into everyday in HVAC/R field service. Measure gas pressure on the inlet and outlets with the standard 3/16” fittings or the included adapters for 5/16” ports, take static pressure measurements across a blower and get the pressure differential with the push of a button to check drafts. Whether you’re holding the ergonomic standalone shape in your hand or hang the SDMN5 on the unit with the magnetic hanger to fill out a work order, the SDMN5 make HVAC/R field service easier and faster, with less fatigue than the other guys.
Features
- Field-replaceable CO sensor
– Easy to install
– Lasts approximately two years
– Comes pre-calibrated - Fast electrochemical sensor helps you find CO sources like cracked heat exchangers or breached flue stacks
- Calibrate to ambient quickly with ZERO button
- Audio and visual alarms (with MUTE function)
- Alarm rate increases as carbon monoxide concentration increases
- MAX hold to help you zero in on the source
- Bright-blue backlit dual-display to test in dark crawl spaces
- Magnetic hanger for hands free testing
- Auto Power Off (APO) to save battery life (easy to disable)
- Battery check with % of battery life left displayed
Specs
- Sensor Type: Electrochemical (specific to CO)
- Sensor Calibration: Factory calibrated @ 17ppm CO and 200ppm CO
- Range: 0 to 1000 ppm; 0 to 2000 ppm (less than 5 minute exposure time)
- Initial Accuracy: @ 73°F±9°F, <75% R.H.
0-15ppm ±5% reading ±1 ppm after zeroing
16-35ppm ±5% reading ±2 ppm after zeroing
36-1000ppm ±5% reading ±5ppm after zeroing - Long Term Drift: less than 5% per year (depending on use)
- CO Air Sample Temperature Range: 32 to 105°F
- Operating Environment: 32 to 122°F (0 to 50°C); 15 to 90% R.H., non-condensing
- Storage Environment: 32 to 68°F (0 to 20°C) at <80% R.H. with battery removed from meter
- Battery: 9V
- Battery Life: 150 hours typical alkaline
- Auto Power Off: After 15 minutes
What's Included
- CO Detector – SCM4
- 9V Battery (installed)
- Operator’s Manual