null

NTI TRX 150 - 15,000/150,000 BTU, 95% AFUE, High Efficiency Natural Gas Condensing Boiler

(No reviews yet) Write a Review
mpn
TRX 150
SKU:
TRX 150
UPC:
628233731678
Info:
Sign in for best pricing
Width:
22.00 (in)
Height:
42.00 (in)
Depth:
20.00 (in)
$3,348.00

Description

Product Features:
Certified to ANSI Z21.13 / CSA 4.9 Gas-fired Boiler Standard
Type 441 Stainless Steel Water Tube Heat Exchanger
ASME “H” stamped boiler, designed and constructed in compliance with the ASME Boiler and Pressure Vessel Code Section IV
Sealed cabinet High energy ignition transformer (spark ignition)
Built-in water pressure bypass (guarantees minimum water flow)
Low water pressure switch
Integrated ECM boiler circulator
Integrated 3-way valve (diverts between DHW & CH demands)
Integrated Condensate Trap
On / Off button
Two 120 VAC outputs for external circulators (DHW/CH)
DHW zone input (tank thermostat or sensor)
CH zone input x 2 (ON/OFF switch or NTI Room Sensor)
WiFi remote connectivity embedded
Outdoor temperature sensor input (or access weather via WiFi connection)

Control Features:
Integral microprocessor safety control – flame safeguard and temperature
TEST Mode – for combustion setup
PURGE cycle – for air purging
AUTO function (outdoor/indoor reset) – resets boiler temperature depending on outdoor and/or room temperature
Adjustable reset curve (slope/parallel shift)
Adjustable reset temperature boost
Summer/Winter changeover (WWSD)
Integrated programmable T-stat x 2 (with optional NTI Room Sensors)
Freeze protection
Factory settings restore option
Cascade up to 8 TRX-series boilers
Adjustable ignition delay timer
Manual mode operation (pump/fan/diverter)
Boiler statistics
Lockout and error history
Optional 0-10V / 4-20mA input clip-in module
Optional NTI 3-Zone Pump/Valve Controller
Optional NTI Room Sensor

Specifications
Minimum / Maximum Input (Btu/Hr): 15,000 / 150,000
AFUE: 95%
Heating Capacity, (MBH): 139
Net AHRI Rating, Water (MBH): 121
Gas Supply Pressure: 3.5” to 10.5” WC
Power Supply: 120V, 60 Hz, less than 12A
Boiler Water Content (Gal): 2
Ignition System: Direct Electronic Spark Ignition / Flame Rectification
Burner System: Premixed Fuel Modulation / Stainless Steel Burner
Gas Valve System: Air Ratio Valve
Gas Connection, NPT: 3/4” (Male)

Manuals & Guides
TRX Installation and Operation Manual
TRX150 & 199 Submittal

View AllClose

Warranty Information

Basic Coverage. Years 1 through 5, 100% coverage. Components Covered All parts (including Pressure Vessel)
View AllClose