Schier GB-250-250HF 4055-031-01 High-Flow, 250 GPM Hydromechanical Grease Interceptor w/ Cast Iron Cover (Liquid Capacity: 277 Gal. Grease Capacity: 1,068 lbs. (146 Gal.)

(No reviews yet) Write a Review
mpn
4055-031-01
SKU:
4055-031-01
Width:
87.00 (in)
Height:
44.00 (in)
Depth:
33.00 (in)
  • Schier GB-250-250HF 4055-031-01 High-Flow, 250 GPM Hydromechanical Grease Interceptor w/ Cast Iron Cover (Liquid Capacity: 277 Gal. Grease Capacity:  1,068 lbs. (146 Gal.)
  • Schier GB-250-250HF 4055-031-01 High-Flow, 250 GPM Hydromechanical Grease Interceptor w/ Cast Iron Cover (Liquid Capacity: 277 Gal. Grease Capacity:  1,068 lbs. (146 Gal.)
  • Schier GB-250-250HF 4055-031-01 High-Flow, 250 GPM Hydromechanical Grease Interceptor w/ Cast Iron Cover (Liquid Capacity: 277 Gal. Grease Capacity:  1,068 lbs. (146 Gal.)
  • Schier GB-250-250HF 4055-031-01 High-Flow, 250 GPM Hydromechanical Grease Interceptor w/ Cast Iron Cover (Liquid Capacity: 277 Gal. Grease Capacity:  1,068 lbs. (146 Gal.)
$5,058.70

Description

High-Flow, 250 GPM Hydromechanical Grease Interceptor

The GB-250-250HF offers best-in-class certified grease capacity and 25% kitchen solids waste capacity. It can be installed above grade (on the ground) or buried below grade (compatible with FCR2 risers to bring the system to grade), as well as indoors or outdoors. The triple outlet feature allows installation flexibility, including connecting an unused outlet for a remote pump out (PP3 compatibility).

Features

  • Rugged polyethylene tank body
  • No flow control is required
  • Safety Star access restrictor prevents accidental entry
  • Fits through 36" doorways

Specs

  1. 4" FPT inlet/outlet with 4" plain end adapters, single inlet, and triple outlet.
  2. Unit weight - w/ cast iron covers: 376 lbs. (For wet weight, add 2,310 lbs.)
  3. Maximum operating temperature: 150° F continuous
  4. Capacities - Liquid: 277 gals. Grease: 1,068 lbs. (146 gal.) @250 GPM Solids: 69 gals.
  5. For gravity drainage applications only.
  6. Do not use it for pressure applications.
  7. Cover placement allows full access to the tank for proper maintenance.
  8. Vent not required unless per local code.
  9. Engineered inlet and outlet diffusers with inspection ports are removable to inspect/clean piping.
  10. Integral air relief / Anti-siphon / Sampling access.
  11. Adjustable cover adapters provide up to 4" of additional height.
  12. Designed for below grade. Above-grade, indoor or outdoor installations.
  13. Safety Star®. Access restrictor built into each cover adapter prevents accidental entry to tanks (450 lb rating).