Description
Resideo S8610U3009 Multi-System Intermittent Pilot Ignition Module
Pilot Ignition Modules and Kits from Resideo are designed to provide easy field replacement of a wide range of OEM intermittent pilot ignition modules. The S8610U Module provides ignition sequence, flame-monitoring and safety shutoff for intermittent pilot central furnaces, residential boilers and other heating appliances.
Features
Honeywell Home Universal Pilot Ignition Module, Intermittent, 24 V AC, Replaces over 400 White-Rodgers, Robertshaw and Honeywell intermittent pilot ignition modules, Provides ignition sequencing, flame monitoring and safety shutoff for intermittent pilot warm air furnaces and heating appliances, Provides 100 percent pilot gas shutoff if pilot fails to light after 6 min delay, trial for ignition is repeated, Ignition trail/delay sequence is repeated until the appliance lights or call for heat is removed, For use with natural or LP gas, For use in single rod or dual rod or remote sense applications, Configurable to 30 sec, No prepurge |
Approvals and Standards | CSA: Design Certified |
---|---|
Type of Fuel | Natural Gas, LPG |
Ignition Type | Intermittent Pilot |
Ignition System Type | Intermittent Pilot |
Pilot Type | Intermittent |
Ignition Source | Internal high voltage spark generator |
Ignition Between Trail Time | 5 minute delay after failed trial for ignition. |
Ignition Sequence | Continuous Retry |
Ignitor Electrical Rating | 24 V AC |
Ignition Trials To Lockout | continuous retry |
Number of Ignition Trials to Lockout | 0 |
Pre-Purge | Configurable to 30 sec or no prepurge |
Lockout Time | Continuous Retry |
Lockout Timing | Continuous Retry |
Flame Failure Response Time | 2 seconds maximum |
Flame Sense | Two Rod, Single Rod |
Early Spark Termination | Yes |
Auto Reset Delay Timing | 1 min |
Thermostat Anticipator Rating | 0.2 A plus pilot valve rating plus main valve rating |
Current Draw | 1 A Pilot Valve|2 A Main Valve |
Power Consumption | 2 VA |
Load Relay Rating | 24 V AC (Amps) 1 A Pilot, 2 A Main at 165 °F, 1A Pilot, 1A Main at 175 °F |
Maximum Valve Load | 1 A Pilot, 2A Main @ 165 °F, 1 A Pilot, 1A Main @ 175 °F |
Power Supply Frequency | 60 Hz |
Frequency | 60 Hz |
Operating Voltage | 24 V AC |
Color | Black |
Compatible With | Intermittent pilot warm air furnaces and heating appliances |
For Use With | Q345, Q348, Q362, Q373, Q381, Q179C, Q354, Q345, Q348, Q362, Q373, Q381 |
Do Not Use With | Do Not Use the 24 V Terminal on S8610U |
Includes | Spark cable adapters to allow field replacement of both Honeywell Home and competitive controls without replacing existing spark cable |
Mounting Type | Mounts in any position except with terminals up, Recommended mounting position is with terminals down to provide maximum protection from dripping water or dust accumulation |
Product Height | 3.94 in, 100 mm |
Product Width | 5.44 in, 138 mm |
Ambient Operating Temperature (Max) | 165 °F, 74 °C |
Ambient Operating Temperature (Min) | -40 °F, -40 °C |