GSA-250-NIP-S1 is discontinued. For a direct replacement, click here (GSA-238-S2) 

"Uncover warm possibilities" with Williamson-Thermoflo's GSA gas fired steam boiler. The highly efficient GSA-250-N-IP pumps out 250,000 BTUs with an AFUE (annual fuel utilization efficiency) rating of 83.0 percent. The GSA is also designed with a generous heating surface and an automatic vent damper to maintain that efficiency. This factory-packaged boiler is equipped with many features, such as a spark (intermittent) pilot system, cast-iron sections, and an insulated heavy-gauge steel jacket. The GSA is also easily serviced with all controls in reach and a one-piece access door. Since it is factory tested and comes with a limited 10 year warranty on boiler sections, you can be absolutely sure that your investment is reliable and built to last.

Specs

  • Input (Btuh): 250,000
  • Heating Capacity (Btuh): 209,000
  • Sq. Ft. Steam: 521
  • Steam BTUH: 125,000
  • AFUE: 82.8%
  • Boiler Water Content: 11.2 gallons
  • Chimney & Breeching Size: 7" I.D. x 20'
  • Return Connection:
  • Height: 33 ¾”
  • Jacket Width: 25 ½"
  • Shipping Weight: 585 lbs.

Features

  • Spark (Intermittent) Pilot System
  • Easy Service
  • One-Piece Access Door
  • All Controls in Easy Reach
  • High Efficiency
  • Generous Heating Surface
  • Automatic Vent Damper
  • Cast Iron Sections
  • Rugged Construction for Long Life
  • Atmospheric (chimney) venting
  • Natural Gas
  • Factory Packaged
  • Integral Cast Iron Legs
  • Integral Draft Diverted
  • Insulated Heavy-Gauge Steel Jacket
  • Heavy-Gauge Aluminized Steel Flue Collector
  • Factory Tested
  • Insulated Heavy-Gauge Steel Jacket
  • Factory-assembled cast iron sections, boiler fully assembled (except GSA-300)
  • Integral  horizontal draft diverted
  • 24-VAC combination gas valve
  • Gauge glass and guard assembly
  • Pressure gauge and siphon assembly
  • Stainless Steel Burners
  • Pressure limit control
  • Probe low water cutoff
  • High temperature limit control
  • Automatic Vent Damper
  • 15 PSIG ASME relieve valve
  • Drain valve
  • Spark-ignited (Intermittent) Pilot System
  • Electronic ignition/flame supervisory control
View AllClose

Warranty Information

Parts Warranty Learn More 1 Year Heat Exchanger Warranty 10 Years
View AllClose