null

Schier GB-50 High-Flow, 50 GPM Indoor/Outdoor Hydromechanical Grease Interceptor w/ Composite Cover (65 Gal. Liquid Capacity)

(No reviews yet) Write a Review
mpn
4025-017-01
SKU:
GB-50
Width:
37.00 (in)
Height:
28.50 (in)
Depth:
32.25 (in)
  • Schier GB-50 High-Flow, 50 GPM Indoor/Outdoor Hydromechanical Grease Interceptor w/ Composite Cover (65 Gal. Liquid Capacity)
  • Schier GB-50 High-Flow, 50 GPM Indoor/Outdoor Hydromechanical Grease Interceptor w/ Composite Cover (65 Gal. Liquid Capacity)
  • Schier GB-50 High-Flow, 50 GPM Indoor/Outdoor Hydromechanical Grease Interceptor w/ Composite Cover (65 Gal. Liquid Capacity)
  • Schier GB-50 High-Flow, 50 GPM Indoor/Outdoor Hydromechanical Grease Interceptor w/ Composite Cover (65 Gal. Liquid Capacity)
  • Schier GB-50 High-Flow, 50 GPM Indoor/Outdoor Hydromechanical Grease Interceptor w/ Composite Cover (65 Gal. Liquid Capacity)
  • Schier GB-50 High-Flow, 50 GPM Indoor/Outdoor Hydromechanical Grease Interceptor w/ Composite Cover (65 Gal. Liquid Capacity)
  • Schier GB-50 High-Flow, 50 GPM Indoor/Outdoor Hydromechanical Grease Interceptor w/ Composite Cover (65 Gal. Liquid Capacity)
$2,042.69

Description

50 GPM Hydromechanical Grease Interceptor

The GB-50 offers best-in-class certified grease capacity and 20% kitchen solids waste capacity. It can be installed above grade (on the ground) or buried below grade (compatible with FCR2 riser to bring system to grade), as well as indoor or outdoor. The triple outlet feature allows for installation flexibility, including the ability to connect an unused outlet for remote pumpout (PP3 compatibility).

Features

  • Rugged polyethylene tank body
  • No flow control required, first in the industry certified to Type D of the ASME standard
  • Safety Star access restrictor prevents accidental entry
  • Fits through 36" doorways
  • A composite cover

Specs 

  1. 4" FPT inlet/outlet with 4" plain end adapters, single inlet, and triple outlet. 
  2. Maximum operating temperature: 150º F continuous 
  3. Capacities - Liquid: 65 gal. Grease: 439.5 lbs. (60 gal.) @50 GPM Solids: 13 gal. 
  4. For gravity drainage applications only. 
  5. Do not use it for pressure applications.
  6. The cover placement allows full access to the tank for proper maintenance.
  7. Vent not required unless per local code.
  8. Engineered inlet and outlet diffusers with inspection ports are removable to inspect/clean piping. 
  9. Integral air relief / Anti-siphon / Sampling access. 
  10. The adjustable cover adapter provides up to 4" of additional height. 
  11. Designed for below-grade, above-grade, indoor or outdoor installations. 
  12. Safety Star, access restrictor built into cover adapter, prevents accidental entry to tank (450 lb rating).